EKRA
Products
  • Relay Protection & Automation
  • Control & Automation Systems
  • Medium-Voltage Drive
  • Low-Voltage Equipment & Systems

Products

Solutions
Services
  • R&D
  • Simulations and Calculations
  • Design Works
  • Adjustment Works
  • Training

Services

Company
  • About EKRA
  • EKRA Group
  • Mission & Values
  • References
  • History
  • Sustainability
  • Press Center

Company

    Support Contacts
    EKRA
    Products
    • Relay Protection & Automation
    • Control & Automation Systems
    • Medium-Voltage Drive
    • Low-Voltage Equipment & Systems

    Products

    Solutions
    Services
    • R&D
    • Simulations and Calculations
    • Design Works
    • Adjustment Works
    • Training

    Services

    Company
    • About EKRA
    • EKRA Group
    • Mission & Values
    • References
    • History
    • Sustainability
    • Press Center

    Company

      Support Contacts
      EKRA
      EKRA
      • Products
        • Back
        • Products
        • Relay Protection & Automation
        • Control & Automation Systems
        • Medium-Voltage Drive
        • Low-Voltage Equipment & Systems
      • Solutions
      • Services
        • Back
        • Services
        • R&D
        • Simulations and Calculations
        • Design Works
        • Adjustment Works
        • Training
      • Company
        • Back
        • Company
        • About EKRA
        • EKRA Group
        • Mission & Values
        • References
        • History
        • Sustainability
        • Press Center
      • Support
      • Contacts
      • Products
      • Relay Protection & Automation
      • Distribution 6–66 kV

      Medium Voltage Protection Relays
      ED2

      Medium Voltage Protection Relays ED2
      Front panel
      Rear view
      Medium Voltage Protection Relays ED2
      Front panel
      Rear view

      Microprocessor devices ED2 are used in medium voltage distribution grids (6–66 kV) to arrange a comprehensive system of protections, automation, control, alarm, registration, disturbance recording and CB state monitoring.

      Devices are designed based on the unified software and hardware platform, which reduces the production time, facilitates project design, operation and maintenance process.

      Front panel

      Graphic display supporting bay mimic diagram with indicated positions of the circuit-breaker, earth switch and withdrawable CB cart, as well as the RMS value of voltage and current, active, reactive and apparent power, network frequency, active and reactive energy

      Buttons for electronic switches with assignable commands (protection enable/disable or other IED functionalities), which reduces the number of operational control switches on the relay compartment door

      24 freely configurable two-color LEDs, which indicate information about tripping of protections and actuation of functions

      Buttons for circuit-breaker control and a keyboard are located on the IED front panel

      Ethernet for PC connection, USB for Flash drive connection

      Rear view

      Depending on the type of protected bay, IED can have 24/24 or 32/16 binary inputs/outpuits. With freely configurable binary inputs/outputs the devices can be easily adapted to the existing relay protection and automation diagrams at the facilities to be reconstructed

      IED has up to 12 analog inputs in various configurations

      Communication ports 2 × RS485, 2 × Ethernet (RJ45 or duplex LC) support the most common protocols for integration to automation system, which allows not only to monitor normal and failure modes of the power system, but also to control the switching devices via digital channels

      Designed for their quick replacement with no need to dismantle the IED

      Replaceable fuse for protection against faults in power supply system

      • 220/250 VDC
      • 110/125 VDC
      • 220 VAC (f=50 Hz)
      Display Electronic switches Two-color LEDs Functional control Functional control IED interfaces Binary inputs and output relays Analog inputs Communication ports Compartment offering access to the IED’s memory card and battery Replaceable fuse Power supply
      • Features
      • Specifications

      Application

      Devices are designed to be installed in relay protection compartments of switchgears or separate cabinets.

      The ED2 versions are designed for:

      • overhead and cable lines,
      • transformers,
      • sectional and incoming CBs,
      • section voltage transformers,
      • motors,
      • static capacitor banks, etc.
      Faulty feeder detector
      The use of ED2 devices in distributed grids is an out-of-the-box solution used to detect a damaged bay in case of single-phase short circuit with a choice of the trip or alarm output signal. No optional equipment is required
      Extended frequency range operation
      Depending on configuration, the device is able to operate within frequency range from 3 to 95 Hz
      8 setting groups
      Up to 8 setting groups may be preset for further quick selection
      Supported protocols
      • Communication protocols: Modbus RTU, Modbus TCP/IP, IEC 60870-5-103, IEC 60870-5-104, IEC 61850-8-1 (GOOSE, MMS)
      • Time synchronization protocols and methods: Modbus RTU/TCP, IEC 60870-5-103/104, SNTP, PPS, IRIG-B003, IRIG-B007
      • Redundency protocols: PRP, Link Backup
      Self-test and test mode
      Devices feature an advanced self-test system, ensuring continuous monitoring of hardware and software serviceability
      Operation conditions
      Devices operate at increased air humidity (≤ 80%), high positive and negative ambient temperatures (continuously from -10 to +55 °C, temporarily from -25 to 60 °C). Devices remain operable within 120 ms after power loss

      ANSI code ED2
      G-0101 T-0201 T-0203 L-0302 D-0303 D-0603 F-0202 F-0301 F-0402 F-0602 M-0501 M-0502 M-0503 C-1601 B-1401 V-1301 V-1501
      87 87G 87T 87T 87L 87M 87B
      21 3
      50/51/67 3 3/2 3/2 3 3 3 2 3 3 3 3 3 3 3 3
      51N
      40
      78
      49R
      -
      -
      50N/51N
      50N/51N
      50N/51N
      27 3
      59
      -
      -
      50BF
      -
      63
      51
      25
      81U
      32R
      49
      37
      50
      -
      -
      -
      -
      -
      79
      -
      -
      79FR
      -
      90V
      -
      -
      -
      21FL
      7I+4U 7I+4U 7I+4U 7I+4U 4I+7U 4I+8U 4I+4U 5I+4U 4I+8U 4I+8U 4I+4U 7I+4U 7I+4U 7I+4U 11I+0U 5I+6U 0I+5U
      24 24 32 24 24 32 32 24 24 24 24 24 24 24 24 24 24
      24 24 16 24 24 16 16 24 24 24 24 24 24 24 24 24 24
      2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      220/250
      110/125
      (220)
      Newsletter subscription
      • Products
        • Relay Protection & Automation
        • Control & Automation Systems
        • Medium-Voltage Drive
        • Low-Voltage Equipment & Systems
      • Services
        • R&D
        • Simulations and Calculations
        • Design Works
        • Adjustment Works
        • Training
      • Company
        • About EKRA
        • EKRA Group
        • Mission & Values
        • References
        • History
        • Sustainability
        • Press Center
      • Support
        • Technical Support
        • Support Offices
        • Video Tutorials
      Contacts
      +7 (8352) 220-110
      +7 (8352) 220-130
      ekra@ekra.ru
      3 Yakovlev prospect, Cheboksary,
      Chuvashia — Chuvash Republic,
      428020, Russia
      2007-2023 © EKRA Research & Production Enterprise Ltd. All rights reserved
      Privacy Policy
      The website ekra.ru uses cookies. By continuing to use this site, you agree to allow us to use cookies in your browser with a view to improving user experience. If desired, you may disable the storage of cookies in your browser settings.